Air Conditioning Service, Repair and Installation

Luxury Climate is one of the leading providers of air conditioning repair and air conditioning service in Chilliwack, BC, offering timely solutions to problems related to your air conditioning system. Our HVAC technicians will come to your rescue when you want emergency AC service or repair, or just need a hand with your residential or commercial cooling problems.

You'll find we take our job seriously and highly value the trust that is placed in us. Luxury Climate goes far beyond what others do by investing in the training and equipment necessary to protect your home or family in Chilliwack, BC. Whether you have a central AC system, Heat Pump or Ductless Mini Split we are here to help.

Get Your Quote Today

Found System Appeared To Be Overcharged On Refrigerant. Weighed Out Charge (7lb 10oz). The Factory Charge Was 6lb 10oz. Added 6lb 12 Oz Of R410a Back Into The System. Checked Operation Of The Heat Pump - Heat Pump Is Creating Correct Temperature Rise Over Indoor Coil. Added UV Dye & Leak Stop To The System To Try & Fix A Leak In The System. If The System Stops Operating Correctly Again, We Will Need To Locate UV Dye & Repair Or Replace The Failed Component.
Rating: starstarstarstarstar
"Very pleased with the workmanship. Fortunate to have William as an HVAC tech. Awesome. Thanks Jerry. "

Jerry , D. Chilliwack, BC
10-12-2021
Compressor Failed. Recovered Refrigerant For Disposal Since The Failed Compressor Contaminated The System. Removed Failed Compressor. Flushed Line Set. Installed New Compressor And Brazed While Purging With Nitrogen. Installed New Drier. Installed New Capacitor And Returned Wiring To Factory. Pressure Tested At 200 Psi For 20 Minutes. Evacuated System To 500 Micron And Charged With 4.5 Lb Or R410A Charging To 10F Sub Cooling. System Is Now Operating Correctly Again.
Davey , J. Chilliwack, BC
08-09-2021
Found Capacitor To Have Failed. The Top Of Capacitor Was Bubbled & Had No Microfarad Reading. Had Replacement On Hand. Installed New Capacitor, Cleaned Outdoor Unit & Tested Operation. System Is Now Operating Again.
Rating: starstarstarstarstar
"After the recent heat dome, our AC unit decided it was tired and stopped working. Will came to look at it last minute and identified the capacitor needed to be replaced. A quick changeover of the part, a cleaning of our unit, and all was good! Will was friendly, informative, professional and very reasonable for cost. Thank you so much! I’d recommend him and his company to anyone needing HVAC services! "

Brynne, H. Chilliwack, BC
08-09-2021
Lennox 13ACX-030
Soap Tested, Used Ultrasonic Detector To Try And Locate Leak. Was Unable To Locate Leak. Tightened All Mechanical Connections. If System Leaks Out Charge Again We Will Have To Spend More Time Trying To Locate. Removed Rubber Couplings From Exhaust Vent Of Furnace. They Are Not Approved For This Use And Were Deteriorating. It Would Have Eventually Resulted In Flue Gases Leaking Into The House. Primed And Glued In Proper 636 Couplings. Venting System Is Now Safe.
Rating: starstarstarstarstar
"TOTALLY HAPPY WITH YOUR SERVICE."

Ingrid, U. Chilliwack , BC
07-14-2021
Air Conditioning Was Not Cooling Properly. Found Circulation Blower Belt On Furnace To Be Very Loose Causing Slipping And Low Air Flow. Blower Wheel Was Dirty. Removed Blower From Furnace And Pressure Washed Outside. Cleaned Outdoor Condenser Coil With Chemical Solution And Pressure Washer.
Amanda & Shawn, C. Chilliwack, BC
06-15-2021
Located Leak On Indoor Coil
Rating: starstarstarstarstar
"Once again, awesome. "

Jerry, D. Chilliwack, BC
06-15-2021